StrainerHome
Strainer Applications
Strainer Products
Strainer Quality
Strainer Unique Features
Contact Strainer Sales
Contact Strainer Support
Get a Job @ Hellan Strainer
The Hellan Strainer Company
Information for US Navy

Single Screen Manual
Automatic

Dual Screen Manual
Automatic

Quad Screen
Manual
Automatic

Six Screen
Manual
Automatic

Welded
Dual Automatic

 

 

Inline Flow Body Dual Screen Strainers

 
 

In Line Flow Hand Operated Strainer -- Available in 2 1/2", 3", 4", 6", 8", 10", and 12" models.  Type DH Hellan Strainers employ two handwheel equipped rotating screens and rigid scraper bars to remove solids from the surface of the screen when the handwheels are rotated. A solids collecting sump is also provided. Cleaning of the type DH is accomplished by opening a valve on the sump flush connection and rotating the handwheels several times. The cleaning cycle must be performed when the strainer is under positive pressure. Type DH strainers can be installed in the vertical up-flow position or in the horizontal flow position with both screens in the horizontal plane, and sump flush connection preferably located at the bottom.

Size
Operation
Flow
Type
Outline Drawing
Pressure Drop Screen
Pressure Drop Wedge
2 1/2"
Hand-Operated
In-Line
DH
N/A
3"
Hand-Operated
In-Line
DH
N/A
4"
Hand-Operated
In-Line
DH
6"
Hand-Operated
In-Line
DH
8"
Hand-Operated
In-Line
DH
10"
Hand-Operated
In-Line
DH
12"
Hand-Operated
In-Line
DH

 

 

 

 

 

 

 

 

 

Inline Flow Automatic Strainer -- Available in 4", 6", 8", 10, and 12" models only. (Type DA) Providing hands-free operation, type DA Hellan Strainers employ two, electric motor-driven rotating screens and rigid scraper bars to remove solids from the surface of the screens when the screens are rotated. A solids collecting sump is also provided. Cleaning of the type DA is initiated when the motor and the flush valve operator are actuated. Controls to accomplish these electrical functions are required. The cleaning cycle must be performed when the strainer is under positive pressure. Type DA strainers can be installed in the vertical up-flow position or in the horizontal flow position with both screens in the horizontal plane, and sump flush connection preferably located at the bottom.

Size
Operation
Flow
Type
Outline Drawing
Pressure Drop Screen
Pressure Drop Wedge
4"
Automatic
In-Line
DA
6"
Automatic
In-Line
DA
8"
Automatic
In-Line
DA
10"
Automatic
In-Line
DA
12"
Automatic
In-Line
DA